Weight processor PW-310 for the batcher of free-flowing materials DWS

Weight processor PW-310 for the batcher of free-flowing materials DWS

PW-310 for the weight batcher for free-flowing materials (DWS) ensures measuring of mass of batched free-flowing materials, automatic control of actuators of the batcher and setting of batching parameters for the purpose of reaching of the set dose value, fixing by the accruing total the amount of doses and total weight of the batched material.

Features:

- control of the actuator of container fixing on the load-receiving device;

- control of the two-position  (double-speed) batching mechanism for filling-up by fast and exact flows;

- control of two vibrators during filling-up of the container with individual setting of the operation  modes;

- control of forced dump / pushing out of the container with the batched material, including, by the external signal of pushing enable;

- control of the actuators position by the external discrete signals;

- stopping and continuation of batching by two external signals;

- start and stop of batching by external signals;

- automatic setting of  batching parameters;

- six- or four-wire connection of the load cell;

- simple calibration of the gear by exemplary weights, and with use of values mV/V of the transmitters;

- non-volatile memory for storage of the journal, totals, settings and real time clock;

- data transmission to peripherals by interface RS-485 or RS-232 with use of the protocol ModBus;

- use of wireless data transmission by means of the portable modem;

- independent setting of batching parameters and independent fixation of doses amount and total weight of the batched material for two values of doses;

- the journal of totals (hour, shift, month, annual);

- the journal of events;

- built-in tests;

- indication of abnormal operation of the batcher (emergencies);

- password protection of settings;

- bilingual interface (Russian / English) of the user;

- possibility of loading of the software at the Customer for its renewal or change of the functionality of the gear.

Power supply

from alteating-current mains with voltage 90 … 260 V, frequency 50 … 60 Hz with use of the integral power supply, or from direct-current mains with voltage 12 … 24 V

Power consumption, VА, no more

10 (without loads connected to discrete exits)

Overall dimensions, mm

280 х 182 х 90

Mass, kg, no more

2,5

Temperature range, °C

from – 10 to + 50 

The display

liquid crystal character with illumination, 16 decades, height of a decade 10 mm

Range of an input analogue signal of direct current voltage, mv

is fixed depending on the operating transmission coefficient of the load cells in ranges 0 - 10, 0 - 20, 0 - 40 and 0 - 80

Range of an output analogue signal of direct current, mA

0…5; 0…20; 4...20

Input of discrete signals

to 8 ports of galvanically disentangled signals of direct current with voltage 12 … 24V

Output of discrete signals

to 8 (16) ports of galvanically disentangled signals of direct current with voltage 12 … 24V and output capacity 0,5 A. The total load no more than 40 VА.

Power supply of the tensoresistive transmitter

5 V of direct current voltage

Amount of connection ports of the tensoresistive transmitters

Number of transmitters

to 8 (at input resistance of transmitters 400 Ohm)

Maximum length of a cable for transmitter connection, m

50 (at 6 wire connection)

Inteal resolution of the measuring channel of transmitters, discharges

24

Industrial resolution, references

40000

Commercial resolution, references

10000

Change of a transformation coefficient from temperature, no more

0,01 %/10 °С

Division value

1; 2; 5х1; 0,1; 0,01; 0,001

Units measure

kg, t, pcs

Control buttons

4 pieces

The serial interface

RS-485 / RS-232 galvanically disentangled

Non-volatile memory (RAM), Kb

8 (482 records in jouals) with real time clock

  • semi-automatic batching of free-flowing materials with automatic control of the two-position (double-speed) batching mechanism of the batcher and automatic setting of batching parameters for the purpose of reaching of the set value of a dose;
  • control of the actuators of container fixing on the load-receiving device;
  • control of two vibrators with individual setting of the operation  modes;
  • start, stop of batching by exteal discrete signals;
  • stopping and continuation of batching by exteal discrete signals;
  • control of presence of the container on the load-receiving device;
  • control of the mechanism of forced pushing out of the container including by the exteal discrete enabling signal;
  • fixation of the dose weight;
  • fixation by the accruing total of amount of doses and total weight of the batched material;
  • automatic stopping of the batcher after execution of the set amount of doses;
  • shaping of the emergency signal at abnormal operation of the batcher with the indication on the display of character of abnormal operation;
  • shaping of the joual of hour, shift, month, annual totals, the joual of events for storage of the information about the executed processes by maintenance personnel (the process title, date and time) and the joual of all emergencies;
  • data transmission to peripherals by interface RS-485 or RS-232 with use of the protocol ModBus.